  • Again, who doesn’t have this access?

    There are communities in northern Ontario that are only accessibly by airplane ~6 months of the year, and those 6 months also have very low amounts of sunlight. They’re not quite north enough to be completely dark all day, but they only get a few hours of useable light per day in the winter.

    This means that a) solar is less effective in the winter, and b) if there is damage to a wind turbine blade in the winter, they may not be able to get a replacement until spring.

    Remote communities don’t have the kind of energy demand that nuclear power fulfills

    Each reactor cell produces about 1MW, which is about enough to power a small town of about 1,000 people. They can also be air-lifted meaning if it needs to be replaced during the winter, that is still possible.










  • As others have said in other posts, the cat’s out of the bag. No matter if/when/how bad the AI crash is, if computing is still viable after then there will be AI.

    I think eventually it will emerge that the highest quality AI code will be produced by already experienced developers, who can identify when it’s produced slop and fix it, and that will be the case no matter how good the models get.

    I of think of it somewhat like managing a team of interns. You give them instructions and they give you code. You still have to know enough to identify if that code meets the requirements and is of good quality.




  • Plastic plumbing is only useful a) up to a certain size since it’s not strong enough to support the weight and pressure beyond, and b) terrible at moving heat across, so it can’t be used in radiators and definitely not in on-die cooling blocks.

    Metal pipes can be coated on the inside to prevent corrosion, but that coating also reduces the amount of heat that transfers out - basically a layer of insulation. This is a big issue that had to be overcome for liquid sodium cooling in reactors, but those don’t need to have a super thin copper plenum on a processor chip, it’s larger pipes moving a larger volume of liquid through a significantly higher temperature difference.

    However, salt water in a secondary, or even tertiary, loop could be used. It would be a similar concept to reactors, where the primary loop is 100% closed and uses a coolant designed for the task, and that then transfers heat through a reverse-flow chiller that’s fed on the other side with salt water. The coolant pipes can be bare copper/aluminum/alloy for better heat transfer and the salt water side can be coated, and the surface area or flow volume just increased to compensate.

    The downside though that can’t be avoided is that your data center now has to be very close to an ocean, and the salt in the air could also cause problems.